Determination of Lasalocid in Animal Feeds by Fluorescence Detection for Contents Lower than 5 mg/kg
Abstrakt
An HPLC method of determination of lasalocid was developed for fast monitoring of its content as an undesirable additive in final fodders. Lasalocid is extracted from a sample with a mixed solvent ethyl acetate - hexane and, after purification of the extract with silica gel, it is determined by HPLC on a reverse C18 phase with fluorescence detection. The determination limit (50 µg/kg), repeatability (0.1 mg/kg) and yield of the method (95 %) were found for lasalocid concentrations 0.5-5 mg/kg. The repeatability was determined for real samples of final fodders.Stahování
Publikováno
15.03.2001
Jak citovat
Dousa, M. (2001). Determination of Lasalocid in Animal Feeds by Fluorescence Detection for Contents Lower than 5 mg/kg. Chemické Listy, 95(2). Získáno z http://ww-w.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/2447
Číslo
Sekce
Články