Removal of Anionic and Non-ionic Surfactants in a Constructed Wetland

Authors

  • Jan Šíma Institute of Chemistry and Biochemistry, Faculty of Science, University of South Bohemia, České Budějovice

Keywords:

wastewater quality treatment, artificial wetland, surfactants, chemical oxygen demand, extraction spectrophotometry

Abstract

Removal of anionic and non-ionic surfactants from wastewater using a constructed wetland with a horizontal subsurface flow was studied. Surfactants were determined by extraction spectrophotometric methods. Anionic surfactants were removed from wastewater with the efficiency 81.7 %. The efficiency increased with increasing temperature of interstitial water and decreased with rising water inflow. Removal of anionic surfactants was influenced by aeration of the wetland bed via roots and rhizomes of vegetation. Oxygen introduced into the wetland accelerated removal of anionic surfactants. The removal of non-ionic surfactants under aerobic or anaerobic conditions was almost complete: its average efficiency was 98.1 %. Organics (expressed as chemical oxygen demand) were removed from treated water with the efficiency 86.4 %. Constructed wetlands can be used as suitable alternatives for treatment of wastewater from small villages. The wetlands are relatively simple and inexpensive. The used extraction spectrophotometric methods are sensitive, precise, and accurate enough for the purpose.

Published

2011-07-15

How to Cite

Šíma, J. (2011). Removal of Anionic and Non-ionic Surfactants in a Constructed Wetland. Chemické Listy, 105(7), 531–537. Retrieved from http://ww-w.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/1117

Issue

Section

Articles

Most read articles by the same author(s)